Few issues create more confusion in perioperative environments than a temporary operating room humidity excursion. When relative humidity rises just above 60%, sometimes by only one or two percentage points, the discussion can quickly turn to delaying procedures or shutting down the OR altogether.
While these decisions are often made with patient safety in mind, they can carry significant consequences:
- Lost operating room time and revenue
- Disruptions to surgeon schedules and block time utilization
- Delays in patient care
- Stress and inconvenience for patients and families who have prepared, fasted, and arranged their schedules
According to NIH literature, the average cost of one minute of operating room time in California hospitals exceeds $37. Even brief interruptions can quickly translate into meaningful operational and financial impacts.
The challenge often stems from confusion between design standards and operational practices, especially as they pertain to regulatory compliance and enforcement.
In 2016, CMS adopted the 2012 edition of NFPA 99 into federal law. This Code references ASHRAE 170, the standard governing ventilation in healthcare facilities. However, ASHRAE 170 was developed primarily as a design standard, not as a day-to-day operational mandate.
In fact, the standard itself, in Section 1. PURPOSE, states clearly that it was developed “…to define ventilation system design requirements…” and acknowledges flexibility within the Footnotes of TABLE 7.1 – design parameters:
“Surgeons or surgical procedures may require room temperatures, ventilation rates, humidity ranges, and/or air distribution methods that exceed the minimum indicated ranges.”
Environmental conditions within healthcare facilities are dynamic. Even well-maintained HVAC systems can experience temporary fluctuations. A brief humidity excursion should be evaluated within the context of the facility’s overall risk assessment rather than automatically triggering operational disruption.
Recognizing this reality, ASHRAE published Guideline 43: Operations Guideline for Ventilation of Health Care Facilities, designed to provide operational guidelines to work in collaboration with the design standard ASHRAE 170; and the white paper entitled Humidity Control Events in Perioperative Care Areas which provides practical guidance for managing humidity fluctuations, drift and other environmental variations, based on the level and duration of the excursion and the capabilities of the system.
Rather than relying solely on rigid thresholds, healthcare organizations should develop practical response protocols based on:
- Clinical and infection prevention risk assessments
- HVAC system capabilities and performance
- Regulatory requirements
- Collaboration among Infection Prevention, Facilities Engineering, and Perioperative Leadership
The most effective organizations recognize that compliance, patient safety, and operational continuity are not competing priorities, they must be managed together through informed, risk-based decision making.
Humidity management in perioperative environments is a complex topic that calls for careful, risk-based planning and thoughtful discussion rather than automatic reactions. Organizations that establish clear, multidisciplinary response plans are often best positioned to maintain compliance, support patient safety, and minimize unnecessary disruptions to care.
I welcome further discussion on this important topic.
Lloyd Duplechan
Hospital COO (Retired) | Healthcare Compliance Consultant
enBio Advisory Board Member

Leave a Reply